Download Print this page
Mitsubishi Electric FR-HEL-C75K Instruction Manual
Mitsubishi Electric FR-HEL-C75K Instruction Manual

Mitsubishi Electric FR-HEL-C75K Instruction Manual

Dc reactor

Advertisement

INVERTER
INSTRUCTION MANUAL
DC Reactor
FR-HEL-C75K to C132K, C185K, C220K, C280K

Advertisement

loading

Summary of Contents for Mitsubishi Electric FR-HEL-C75K

  • Page 1 INVERTER INSTRUCTION MANUAL DC Reactor FR-HEL-C75K to C132K, C185K, C220K, C280K...
  • Page 2 Thank you for choosing this Mitsubishi Inverter option. This instruction manual gives handling information and precautions for use of this equipment. Incorrect handling might cause an unexpected fault. Before using the equipment, please read this manual carefully to use the equipment to its optimum. Please forward this instruction manual to the end user.
  • Page 3 4. Additional Instructions 2) Trial run Also note the following points to prevent an CAUTION accidental failure, injury, electric shock, etc. Assumes that incorrect handling may cause  Before starting operation, confirm and an accidental failure, injury, electric shock, adjust the parameters. A failure to do so etc.
  • Page 4: Table Of Contents

    Contents Product Checking................2 Installation ..................2 Wiring ....................3 Cable Size and Crimping Terminal ..........4 Specifications .................. 5 Outline Dimension Drawings ............5 APPENDIX....................8...
  • Page 5: Product Checking

    (1) Unpack the option unit, and ensure that the product received is as you ordered and it is intact. DC REACTOR MODEL XXXXXXXXXXX FR-HEL-C SERIAL MITSUBISHI ELECTRIC CORPORATION FR-HEL- C Applied motor capacity (kW) Symbol Applied Power Supply Voltage 600V class (2) Make sure that the package includes all accessories.
  • Page 6: Wiring

    Wiring Wiring (1) When using the inverter equipped with a jumper across terminals P1 and P, remove the jumper and connect the reactor across terminals P1 and Minimize the connection cable between the reactor and inverter so that the  length is within 5m.
  • Page 7: Cable Size And Crimping Terminal

    Refer to page 3 for the wiring of terminals P and P1 and the earthing cable. P, P1 Earth (ground) cable Tightening Model Terminal Crimping AWG/ Crimping AWG/ torque* bolt size terminal terminal Nm FR-HEL-C75K 26.5 60-10 38-6 FR-HEL-C90K 26.5 70-10 38-6 FR-HEL-C110K 26.5 80-10 38-6 FR-HEL-C132K 46.1 100-12...
  • Page 8: Specifications

    The value is 94.4% when calculated with 1 power factor for the fundamental wave according to the Architectural Standard Specifications (Electrical Installation) (2013 revision) supervised by the Ministry of Land, Infrastructure, Transport and Tourism of Japan. Outline Dimension Drawings FR-HEL-C75K  2-terminal Rating plate (for M10 bolt)
  • Page 9 Outline Dimension Drawings FR-HEL-C90K to C132K  Rating plate 2-terminal (for φ bolt) P1, P 4-installation hole (for S screw) Within D Earth (ground) terminal (for S1 screw) Motor Mass  Model capacity (kg) FR-HEL-C90K 90kW FR-HEL-C110K 110kW FR-HEL-C132K 132kW Unit (mm)
  • Page 10 Outline Dimension Drawings FR-HEL-C185K, C220K, C280K  Rating plate 2-M8 eye nut φ 2-terminal (for bolt) 4-installation hole (for S screw) Within D Earth (ground) terminal (for S1 screw) * Remove the eye nut after installation of the product. Motor Mass ...
  • Page 11: Appendix

    The FR-HEL-C series are a UL Listed accessory for use only with the following UL listed inverter models: • 600V class DC reactor model Applicable inverter models FR-A860-01080, 01440, 01670 FR-HEL-C75K FR-F860-01080, 01440, 01670 FR-AF860-01080, 01440, 01670 FR-A860-01440, 01670, 02430 FR-HEL-C90K FR-F860-01440, 01670, 02430...
  • Page 12 (page 8) is compatible with the conventional model as shown in the table below. If the compatible conventional model is already obtained, it can be used as FR-HEL-C series reactor Conventional model FR-HEL-C75K BKO-CA1901H01 FR-HEL-C90K BKO-CA1901H02 FR-HEL-C110K BKO-CA1901H03...
  • Page 13 MEMO...
  • Page 14 MEMO...
  • Page 15 REVISIONS *The manual number is given on the bottom left of the back cover. Print Date *Manual Number Revision Feb. 2015 IB(NA)-0600587ENG-A First edition Oct. 2016 IB(NA)-0600587ENG-B Addition • Compatibility with the FR-F860 series and the FR-AF860 series...
  • Page 16 HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN IB(NA)-0600587ENG-B(1610)MEE Printed in Japan Specifications subject to change without notice.