3.6

Parameter copy and parameter verification

PCPY Setting
0
Cancel
1
Copy the source parameters to the operation panel.
2
Write the parameters copied to the operation panel into the destination converter.
3
Verify parameters in the converter and operation panel. (Refer to page 122)
REMARKS
 When the copy destination is other than the FR-HC2 series converter or when parameter copy is attempted after the parameter
copy reading was stopped, "model error (
 Refer to page 188 for the availability of parameter copy.
 When the power is turned OFF or an operation panel is disconnected, etc. during parameter copy writing, write again or check
the setting values by the parameter verification.
 After a parameter copy, the operation of the converter is in a stop status. Reset the converter after a parameter copy is
completed.
(1)
Parameter copy
Parameter settings can be copied to multiple converters.
Operation
1.
Connect the operation panel to the
copy source converter.
2.
Press
to choose the parameter
setting mode.
3.
Turn
until
appears.
4.
Press
to read the currently set value.
"
"(initial value) appears.
5.
Turn
to change it to the setting value
" ".
6.
Press
to copy the source parameters
to the operation panel.
7.
Connect the operation panel to the
copy destination converter.
8.
After performing the steps 2 to 5,
turn
to change it to "
9.
Press
to write the parameters copied to
the operation panel to the destination converter.
10.
When copy is completed,
"
" and "
11.
After writing the parameter values to the copy
destination converter, always reset the converter,
e.g. switch power OFF once, before starting operation.

Parameter copy and parameter verification

Description
)" appears.
(parameter copy)
About 30s later
".
" flicker.
Display
The parameter
number previously
read appears.
Flickers for about 30s
Flicker ··· Parameter copy complete!!
The frequency flickers
Flicker ··· Parameter copy complete!!
for about 30s
121
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-hc2-h7.5kFr-hc2