Installation; Converter Placement - Mitsubishi Electric FR-HC2-7.5K Instruction Manual

Hide thumbs Also See for FR-HC2-7.5K:
Table of Contents

Advertisement

2.3

Installation

Incorrect installation and connection may cause the equipment to operate improperly and its lifespan to be reduced
considerably. Please handle the unit properly in accordance with the information on each section as well as the precautions in
this manual.
2.3.1

Converter placement

(1)
Installation of the converter
Installation on the enclosure
7.5K, 15K
 The converter consists of precision mechanical and electronic parts. Never install or handle it in any of the following
conditions as doing so could cause an operation fault or failure.
Direct sunlight
Vertical mounting
(When installing two or
more converters, install
them in parallel.)
30K or higher
Fix six points for 160K to 280K, and eight
points for 400K and 560K.
Vibration
2
(5.9m/s
or more at 10
to 55Hz (directions of X,
Y, Z axes))
2
 2.9m/s
or more for the
160K or higher
Transportation by
holding the front cover
NOTE
 When encasing multiple converters, install
them in parallel as a cooling measure.
 Install the converter vertically.
Refer to the clearance
on the next page.
High temperature,
Horizontal placement
high humidity
Oil mist, flammable
Mounting to
gas, corrosive gas,
combustible material
fluff, dust, etc.

Installation

Vertical
2
19