6
Gas heating
Manual
previous page
Control the operation of the
ionization electrode
Detection of
Not detection
flame, but the
of flame
ignition stops
after 5 seconds
1. Check the cable of the
electrode
Call the factory
2. Check the distance between
After Sales Department
the electrode and the ceramic
plate (± 2 mm / ceramic plate)
ceramic plate
electrode
gas pipe burner