Operation

Smoothing motors M3 and M4 :

Connected to the A2 feeder interconnection board (J215 and J214), the M3 and M4 motors are
powered on and off by the KM203 contactor.

Contactor KM203 :

Connected to the A2 feeder interconnection board, the KM203 contactor is controlled by the
Q0.6 output on the A1 feeder PLC and powers on and off the M3 and M4 smoothing motors.

Inductive detector B203 :

Connected to the A2 feeder interconnection board (J209), the induction detector allows the A1
feeder PLC to stop smoothing.
2
Feeding : Smoothing system
Power supply
Q201
KM203
M3
M4
A2 Feeder
interconnection board
J203
B203
J202.4
A1 TWIDO
Q0.6
Feeder PLC
Service