Electrolux IC44832 LF Service Manual page 172

Flatwork ironers
Table of Contents

Advertisement

15
Service Option
Value
Set 1
p1 and p2 potentiometers settings
Moisture: 000
Moisture In: 011
p1
p2
board n°1
• P2 potentiometer :
Turn the screw of the P2 potentiometer in a direction or the other to adjust the value
'Moisture' with a value superior to 200 and only then, lower this value until obtaining 000.
ATTENTION : DON'T LOWER BELOW 000.
• P1 Potentiometer :
Turn the screw of the P2 potentiometer in a direction or the other to adjust the value
'Moisture In' with a value superior to 200 and only then, lower this value until obtaining a
value between 10 and 15.
When settings are completed, push on the center key to exit the menu.
6
DIaMMS kit
• The «Service Option» menu displays as opposite.
• Press on «Set 1».
Set 2
• After completing the adjustments, put back the left
side frame of the machine.
Scroll menus with the left key up to the menu here
opposite.
aTTeNTION : the setting of the potentiometer (p1 &
p2) must be done with running hot ironer (≈ 150°C)
and without sheet inside.
P1 potentiometer: Moisture In temperature
P2 potentiometer: Moisture Out temperature
Service
Manual
board n°1
board n°2
04106016/GB
43-09

Hide quick links: