Service
Manual
Before any intervention it is essential to cut off all supply of the machine
Repair
Rotation detection B8 :
Checking
- Check the wiring.
- Machine running, check that the detector's indicator is blinking, otherwise, the detector is
faulty.
Replacing
- Remove the machine's left cover.
- Remove the detector from its bracket.
- Disconnect the orange wire from the detector.
- Connect the orange wire to the new detector.
- Fit the new detector to the bracket.
- Adjust the detector to ensure it detects the pulses created by the rotation detection disc.
- Close the cover.
position sensors B9 and B10 :
Checking
- Check the wiring.
- Power on the machine, check that the I0.5 and I0.6 inputs on the A4 folder PLC are lit when
a metallic object is laid on the detectors B9 and B10. Otherwise, the detectors are faulty
Replacing
- Remove the machine's left cover.
- Remove the faulty detector from its bracket.
- Disconnect the orange cable from the detector.
- Connect the orange cable on the new detector.
- Fit the new detector on the appropriate bracket.
- Set the detector according to the arm's position.
- Close the cover.
04106016/GB
43-09
Length folding
(electricity, steam, water, gas, compressed air...).
9
13