6
a5_Control rotation
X103
* sonde PT100
Degré °C
Ohms
15
105.46
16
106.24
17
106.63
18
107.09
19
107.40
20
107.79
21
108.18
22
108.57
23
108.96
24
109.35
25
109.73
26
110.12
27
110.51
28
110.90
29
111.29
30
111.67
31
112.06
32
112.45
33
112.83
34
113.22
35
113.61
16
Gas heating
previous page
Control the rotation sensor
B13 (A5: J103-1/J103-2/J103-3)
Good
Control the temperature sensors
B20, B21, B22
PT100* (A1, X2)
Good
BP4
If one of the three
sensors displays a
sign '+' in the place of
a numerical value that
means that this sensor
is faulty.
Opposite, it is the T2
sensor which is faulty
next page
Bad
Stop all supply of the machine
Bad
Activate the «Service Option»
mode using the BP4 push button
which is on the back of the
T1: 150°C T2: +
C: 1
Stop all supply of the machine
Service
Manual
and replace the faulty
rotation sensor
control display
Select «Value» menu
Service Option
Value
Set 1
Set 2
Sensor T1: OK
T3: 150°C
Sensor T2: XX
Fan1: 0
Fan2:0
Sensor T3: OK
and replace the faulty
temperature sensor