Operation; Suction Motor M5; Contactor Km204 - Electrolux IC44832 LF Service Manual

Flatwork ironers
Table of Contents

Advertisement

13
Feeding : Feeding table with suction
Q201
KM204

Operation

Suction motor M5 :

Connected to the A2 feeder interconnection board (J217), the M5 suction motor is powered on
and off by the KM204 contactor. It is used to hold the sheet on the feeding table by suction.

Contactor KM204 :

Fitted on the A2 feeder interconnection board, the KM204 contactor is controlled by the Q0.7
output on the A1 feeder PLC. It is used to power on and off ventilation motor M5.
2
Power supply
J202
A2 Feeder interconnection board
J217
M5
A1 feeder PLC
Q0.7
Service
Manual
04106016/GB
43-09