Operation; Position Switches Fc4, Fc5, Fc201, Fc202 And Fc203; Push Button Indicator Bp202 / H201; Push Button Bp3 And Bp201 - Electrolux IC44832 LF Service Manual

Flatwork ironers
Table of Contents

Advertisement

Service
Manual

Operation

position switches FC4, FC5, FC201, FC202 and FC203 :

Connected to the A3 interconnection board (J224), the FC4 end stop is used by the A1 feeder
PLC to detect the clamps position when opening up.
Connected to the A3 interconnection board (J225), the FC5 position switch is used by the A1
feeder PLC (I0.9) to detect the position of the claws when they are closing.
Connected to the A2 feeder interconnection board (J207A), the FC201 position switch is used
by the A1 feeder PLC (I0.5) to detect the end stop of the feeding carriage in the « clamps for-
ward » mode.
Connected to the A2 feeder interconnection board (J207B), the FC202 position switch is used
by the A1 feeder PLC (I0.6) to detect the end stop of the feeding carriage in the « clamps cen-
tred » mode.
Connected to the A2 feeder interconnection board (J207C), the FC203 position switch is used
by the A1 feeder PLC (I0.7) to detect the end stop of the feeding carriage in the « clamps back »
mode.

push button indicator Bp202 / h201 :

Connected to the A3 interconnection board (J223), the H201/BP202 pushbutton indicator is
used to notify the operator of a fault on the feeder and reset the feeder by pressing it.

push button Bp3 and Bp201 :

Connected to the A3 interconnection board (J223), the BP3 pushbutton is used by the A1 feeder
PLC (I0.0) to stop the machine at any time.
Connected to the A3 interconnection board (J223), the BP201 pushbutton is used by the A1
feeder PLC (I0.1) to start the feeder cycle.

Switch 3 positions S201 :

Connected to the A3 interconnection board (J223), the S201 switch is used by the A1 feeder
PLC (I0.3 & I0.4) to select 3 different operating modes for the feeder : mode with feeding, mode
with semi-automatic feeding, and mode without feeding.

potentiometer p1 :

Connected to the A4 interconnection board (J253), potentiometer P1 is used to adjust the clamp
strength.

Motors M1 and M2 :

Connected in the A4 interconnection board (J252), motor M2 is powered on and off by output
Q0.4 on the A1 feeder PLC. It is used to open and close the clamps.
Connected to the A2 feeder interconnection board (J213), the M1 motor reducer is powered on
and off by the KM201 and KM202 contactors. It is used to push and pull the clamps to lay the
sheet on the feeding table.
04106016/GB
43-09
Feeding : Motion system
12