Service
Manual
Before any intervention it is essential to cut off all supply of the machine
Repair
positions switch S8 and S9 :
Checking
- Check the wiring.
- Using an ohmmeter, check the ohmic value between the switch's two contacts in the
actuated position. If the value is other than 0, the switch is faulty
Replacing
- Remove the machine's left cover for the S8 switch.
- Remove the switch from its housing.
- Disconnect the switch cable.
- Connect the cable on the new switch.
- Fit the new switch in its appropriate location.
- Close the cover.
Contactors KM3, KM4 and KM5 :
Checking
- Check the wiring.
- Power on the machine, supply the contact coil manually, and check the contacts. If the
contacts do not stick, the contactor is faulty.
Replacing
- Remove the left cover.
- Disconnect the cables on the faulty contactor.
- Remove the contactor and fit a new one.
- Reconnect the cables.
- Close the cover.
04106016/GB
43-09
Length folding
(electricity, steam, water, gas, compressed air...).
9
15