Service
Manual
Before any intervention it is essential to cut off all supply of the machine
Repair
Suction motor M5 :
Checking
- Check the wiring.
- Power on the machine, supply the coil on the KM204 contactor manually, and check the
motor is running. Otherwise, the motor is faulty.
Replacing
- Disconnect the cables from the motor.
- Remove the bracket + ventilation motor + stringer volute assembly from the machine.
- Remove the bracket volute.
- Remove the turbine.
- Remove the motor from the bracket and fit a new one
- Refit the parts in the reverse sequence.
Contactor KM204 :
Checking
- Check the wiring.
- Power on the machine, supply the contactor coil manually, and check proper operation of
the contacts. If the contacts do not stick, the contactor is faulty.
Replacing
- Remove the left cover on the feeding system.
- Disconnect all the cables connected to the A2 feeder interconnection board
- Change the A2 feeder interconnection board.
- Refit the parts in the reverse sequence
04106016/GB
43-09
Feeding : Feeding table with suction
(electricity, steam, water, gas, compressed air...).
13
5