Service
Manual
Before any intervention, it is essential that all machine feeds be cut

Code errors on display

Overheating of cylinder sides (when feeding is
carried out on the centre of the cylinder too often)
This error displays alternately with the service screen
when one of the two sides of the cylinder overheats
due to it being partially used. The heating system of
the machine will remain shut down while this flashing
message is displayed. To continue ironing, allow the
cylinder to cool until the flashing display disappears.
Overheating of centre of cylinder (when small linen
units are too often fed on the centre of the cylinder) :
This error displays alternately with the service screen
when the centre of the cylinder overheats due to it being
used laterally. The heating system of the machine will
remain shut down while this message continues to be
displayed. To continue ironing, allow the cylinder to cool
until the flashing display disappears.

Message : 'Converter failure'

This error displays alternately with the service screen
when the converter has developed a fault. Please refer to
the converter manual for information repairing the fault.
The machine will only be able to be restarted once the
fault has been repaired. To re-initialise the machine, press
any key. If the fault remains, switch off then switch back
on the power supply using the main switch.

Message : 'emergency stop-check button'

This error displays alternately with the service screen
when the emergency stop button has been triggered. The
machine enters safety mode, the heating is turned off and
the cylinder stops. Check why the button was pressed
and then reset it.
04106016/GB
43-09
Troubleshooting
(electricity, steam, water, compressed air...)
error
Overheating on side
error
Overheating
CONVeRTeR FaILURe
pReSS aNY KeY
eMeRGeNCY STOp
ReSeT push-button
30