Description; Heating Elements - Electrolux IC44832 LF Service Manual

Flatwork ironers
Table of Contents

Advertisement

Service
Manual

Description

The system « Electric heating with air circulation » includes the following elements :

* 9 Heating elements

* 1 Air circulation control plate :
- 3 Contactors : KM6, KM7 & KM8
- 2 Motor contactors : KM9 & KM10
- 1 Three-pole breaker : Q2
* 2 Ventilation motors: M4 & M5
* 3 Temperature sensors : B20, B21 & B22
* 1 Temperature safety sensor : B3 (B1 DUBIXIUM option)
Heating element power according to the type of machine :
• IC4 4819
• IC4 4821
• IC4 4825
The heating elements are fitted on a bracket housed inside the ironing cylinder.
Both ventilation motors M4 (left side) and M5 (right side) are fitted at both ends of the ironing
cylinder. They are accessible by removing the machine's right and left covers.
The KM6, KM7, and KM8 contactors are fitted on the machine's electrical heating base plate.
They are accessible by removing the left cover on the machine.
The three temperature probes B20 (left sensor), B21 (centre sensor), B22 (right sensor) and the
safety sensors B3, B1 are fitted in direct contact with the ironing cylinder. They are accessible
through the front of the machine under the folding table.
04106016/GB
43-09
electrical heating with air circulation
3650W / 400V
4050W / 400V
4800W / 400V
• IC4 4828
5200W / 400V
• IC4 4832
5950W / 400V
5