2.
Configure the parameters as required.
3.
Click the Submit button to save your changes, or click the Subscribe to MWI or
Unsubscribe to MWI buttons to save your changes and to subscribe / unsubscribe to
the MWI server.
4.
To save the changes to flash memory, refer to ''Saving Configuration'' on page 237.
3.4.5.6.3 Configuring Metering Tones
The FXS interfaces can generate 12/16 KHz metering pulses towards the Tel side (e.g., for
connection to a payphone or private meter). Tariff pulse rate is determined according to an
internal table. This capability enables users to define different tariffs according to the source
/ destination numbers and the time-of-day. The tariff rate includes the time interval between
the generated pulses and the number of pulses generated on answer.
Note:
To configure the Metering tones:
1.
Open the 'Metering Tones' page (Configuration tab > Protocol Configuration menu
> SIP Advanced Parameters submenu > Metering Tones page item).
2.
Configure the Metering tones parameters as required. For a description of the
parameters appearing on this page, refer to ''Configuration Parameters Reference'' on
page 291.
3.
Click the Submit button to save your changes.
4.
To save the changes to the flash memory, refer to ''Saving Configuration'' on page
237.
If you set the 'Generate Metering Tones' parameter to 'Internal Table', access the 'Charge
Codes Table' page by clicking the Charge Codes Table
description on configuring the Charge Codes table, refer to ''Charge Codes Table'' on page
172.
Version 5.8
The 'Metering Tones' page is available only for FXS interfaces.
Charge Code rules can be assigned to routing rules in the 'Tel to IP
Routing' table (refer to ''Configuring the Tel to IP Routing Table'' on page
201). When a new call is established, the 'Tel to IP Routing' table is
searched for the destination IP address. Once a route is located, the
Charge Code (configured for that route) is used to associate the route
with an entry in the 'Charge Codes' table.
Figure 3-150: Metering Tones Page