Parameter
Web: Gateway Registration Name
EMS: Name
[GWRegistrationName]
Web/EMS: Authentication Mode
[AuthenticationMode]
Set Out-Of-Service On Registration
Failure
EMS: Set OOS On Registration Fail
[OOSOnRegistrationFail]
SIP User's Manual
Defines the user name that is used in the From and To
headers in REGISTER messages. If no value is specified
(default) for this parameter, the UserName parameter is used
instead.
Note: This parameter is applicable only for single registration
per device (i.e., AuthenticationMode is set to 1). When the
device registers each channel separately (i.e.,
AuthenticationMode is set to 0), the user name is set to the
channel's phone number.
Determines the device's registration and authentication
method.
[0] Per Endpoint = Registration and Authentication
separately for each endpoint.
[1] Per Gateway = Single Registration and Authentication
for the entire device (default).
[3] Per FXS = Registration and Authentication for FXS
endpoints.
Typically, Authentication per endpoint is used for FXS
interfaces,where each endpoint registers (and authenticates)
separately with its own user name and password.
Single Registration and Authentication (Authentication Mode =
1) is usually defined for FXO ports.
Enables setting an endpoint or the entire device (i.e., all
endpoints) to out-of-service if registration fails.
[0] Disable = Disabled (default).
[1] Enable = Enabled.
If the registration is per Endpoint (i.e., AuthenticationMode is
set to 0) or Account (refer to ''Configuring the Trunk Group
Settings'' on page 222) and a specific endpoint/Account
registration fails (SIP 4xx or no response), then that endpoint
is set to out-of-service until a success response is received in
a subsequent registration request. When the registration is per
the entire device (i.e., AuthenticationMode is set to 1) and
registration fails, all endpoints are set to out-of-service.
The out-of-service method is set according to the parameter
FXSOOSBehavior.