Direct Inward Dialing Parameters - AudioCodes mediapack MP-500 User Manual

Msbg
Table of Contents

Advertisement

Parameter

6.8.11 Direct Inward Dialing Parameters

The Direct Inward Dialing (DID) parameters are described in the table below.
Parameter
Web/EMS: Enable DID
Wink
[EnableDIDWink]
Web/EMS: Delay Before
DID Wink
[DelayBeforeDIDWink]
SIP User's Manual
(configured by the parameter HotLineToneDuration), the
destination phone number is automatically dialed.
Module = Module number (where 1 depicts the module in Slot 1).
Port = Port number (where 1 depicts the Port 1 of the module).
For example:
TargetOfChannel 0 = 1002,1,1,1;
dialed for Port 1 of Module 1)
TargetOfChannel 1 = 101,1,1,2;
dialed for Port 2 of Module 1)
Notes:
The indexing of this ini file table parameter starts at 0.
Define this parameter for each device port that implements Automatic
Dialing.
After a ring signal is detected on an 'Enabled' FXO port, the device
initiates a call to the destination number without seizing the line. The
line is seized only after the call is answered. After a ring signal is
detected on a 'Disabled' or 'Hotline' FXO port, the device seizes the
line.
For configuring this table using the Web interface, refer to ''Configuring
Automatic Dialing'' on page 213.
For an explanation on using ini file table parameters, refer to ''Format of
ini File Table Parameters'' on page 273.
Table 6-40: DID Parameters
Enables Direct Inward Dialing (DID) using Wink-Start signaling.
[0] Disable = Disables DID Wink(default).
[1] Enable = Enables DID Wink.
If enabled, the device can be used for connection to EIA/TIA-464B DID
Loop Start lines. Both FXO (detection) and FXS (generation) are
supported. An FXO interface dials DTMF digits after a Wink signal is
detected (instead of a Dial tone). An FXS interface generates the Wink
signal after the detection of off-hook (instead of playing a Dial tone).
Defines the time interval (in msec) between detection of off-hook and
generation of a DID Wink.
The valid range is 0 to 1,000. The default value is 0.
Note: This parameters is applicable only to FXS interfaces.
380