Parameter
Web: CDR Server IP
Address
EMS: IP Address of CDR
Server
[CDRSyslogServerIP]
Web/EMS: CDR Report
Level
[CDRReportLevel]
Web/EMS: Debug Level
[GwDebugLevel]
Web: Activity Types to
Report via Activity Log
Messages
[ActivityListToLog]
SIP User's Manual
Defines the destination IP address to where CDR logs are sent.
The default value is a null string, which causes CDR messages to be
sent with all Syslog messages to the Syslog server.
Note: The CDR messages are sent to UDP port 514 (default Syslog
port).
Determines whether Call Detail Records (CDR) are sent to the Syslog
server and when they are sent.
[0] None = CDRs are not used (default).
[1] End Call = CDR is sent to the Syslog server at the end of each
call.
[2] Start & End Call = CDR report is sent to Syslog at the start and
end of each call.
[3] Connect & End Call = CDR report is sent to Syslog at connection
and at the end of each call.
[4] Start & Connect & End Call = CDR report is sent to Syslog at the
start, at connection, and at the end of each call.
The CDR Syslog message complies with RFC 3161 and is identified by:
Facility = 17 (local1) and Severity = 6 (Informational).
Syslog debug logging level.
[0] 0 = Debug is disabled (default).
[1] 1 = Flow debugging is enabled.
[2] 2 = Flow and device interface debugging are enabled.
[3] 3 = Flow, device interface, and stack interface debugging are
enabled.
[4] 4 = Flow, device interface, stack interface, and session manager
debugging are enabled.
[5] 5 = Flow, device interface, stack interface, session manager, and
device interface expanded debugging are enabled.
Note: Usually set to 5 if debug traces are needed.
The Activity Log mechanism enables the device to send log messages
(to a Syslog server) for reporting certain types of Web operations
according to the below user-defined filters.
[PVC] Parameters Value Change = Changes made on-the-fly to
parameters.
[AFL] Auxiliary Files Loading = Loading of auxiliary files (e.g., via
'Certificate' page).
[DR] Device Reset = Reset of device via the 'Maintenance Actions'
page.
[FB] Flash Memory Burning = Burning of files or parameters to flash
(in 'Maintenance Actions' page).
[SWU] Device Software Update = cmp file loading via the Software
Upgrade Wizard.
[ARD] Access to Restricted Domains = Access to restricted domains,
which include the following Web pages:
(1) ini parameters (AdminPage)
(2) 'General Security Settings'