Using The Built-In Iconfig Scripts; Adding Options Manually - HPE AlphaServer 300 User Manual

Table of Contents

Advertisement

KEY HELP: Arrows/TAB to move, RET once to submit entry, RET
2nd time to exit

Using the Built-in ICONFIG Scripts

There are three types of options that can be configured into the AlphaServer 300 system
using a built-in script: the DE205 Ethernet module, PBXJA-AA sound module, and
PB2GA-FB graphics module (MACH 64). You can use a script to configure only one
module of each type. Enter the help scripts command to view the available scripts. (Note
that the PCXDF-AA fax/modem module is not supported on the AlphaServer 300.)
>>>help scripts
NAME
scripts
FUNCTION
These scripts are used to set up the system
configuration.
SYNOPSIS
Available scripts:
add_de205
add_fax
add_sound
add_mach64
To add a module, type the script name. You must also type init to submit the entry. For
example, add a PB2GA-FB (MACH64) graphics module as follows:
>>> add_mach64
>>> init
After the system initializes, type iconfig to view the configured options. The MACH64
module now appears in the display, and you can turn off the system and install the module.

Adding Options Manually

If you are configuring more than one of the same type of ISA option (for example, two
non-Digital Ethernet options), you must enter the configuration information manually.
3-18 AlphaServer 300 User's Guide
Adds DE205 module
Adds FAX module
Adds SOUND module
Adds ATI-MACH64 module