HPE AlphaServer 300 User Manual page 101

Table of Contents

Advertisement

apu-version 959328854 *** Firmware Update Utility V2.9 ***
*** System Type: AlphaServer 300***
Update
VERify
List
Show
DUmp
VERBose
NVerbose
DEbug
NDebug
?
Apu>
_________________________ NOTE_____________________________
The commands displayed above can be entered on the utility command line.
The update command must be entered in full. The other APU commands can
be abbreviated. The minimum characters required are shown in capital letters.
Commands such as Dump, List, Show, and Verify must have verbose mode
enabled for their output to be displayed. Type the Verbose command at the
Apu-> prompt to enter verbose mode.
____________________________________________________________
4. To update the firmware, type update. The following information will be displayed
as the firmware is being updated.
Apu-> update
APU-I *** ROM 0,1 Contents will be destroyed ***
APU-I Are you ready to Program Device? (y/n)y
APU-I Programming device
APU-I Programming device completed
APU-I Programming device
APU-I Programming device completed
Apu->
5. Use the verify command to verify the integrity of the SRM firmware. First enable
verbose mode by typing verbose; then type verify.
Apu-> verbose
Apu-> verify
B–4 AlphaServer 300 User's Guide