Using the Flash Update Utility from the SRM Console

To update the firmware from the SRM console, do the following:
1. Insert the Firmware Update CD-ROM into the CD drive.
2. Type the show device command to determine the device ID of the CD drive.
>>>show device
dka0.0.0.6.0
dka400.4.0.6.0
dva0.0.0.0.1
ena0.0.0.1.1
pka0.7.0.6.0
3. Boot the Firmware Update Utility CD-ROM using the device ID displayed in step 2.
(If you are using the update floppy, the device ID would be dva0.)
>>>b dka400
You should see a display similar to the following, while the update utility is loading
and executing:
Bootfile: [alpha200]as200_v2_8.exe
bootstrap code read in
base = 11e000, image_start = 0, image_bytes = ea800
initializing HWRPB at 2000
initializing page table at 110000
initializing machine state
setting affinity to the primary CPU
jumping to bootstrap code
ff.fe.fd.fc.fb.fa.f9.f8.f7.f6.f5.
ef.df.ee.ed.ec.f4.eb.....ea.e9.e8.e7.e5
X3.7-10895, built on Sep 13 1994 at 11:29:42
>>>Execute Update Sequence
Update Script Complete
(boot pmem:180000 -flags 0,0)
bootstrap code read in
base = 180000, image_start = 0, image_bytes = 800000
initializing HWRPB at 2000
initializing page table at 710000
initializing machine state
setting affinity to the primary CPU
jumping to bootstrap code
DKA0
RZ26L
DKA400
TOSHIBA CD-ROM
DVA0
ENA0
08-00-2B-38-67-6B
PKA0
SCSI Bus ID 7
440C
0064
Updating System Firmware B–3