5-6. DO NOT DISTURB

Aug. 2014
Time periods of peak operations during which the "FILTER
NOW?" message will not appear, may be programmed into the
fryer. There are three groupings of days - Monday thru Friday
(M-F), Saturday (SAT), and Sunday (SUN). Within each day
grouping, up to 4 time periods (M-F 1 thru M-F 4, SAT 1 thru
SAT 4, and SUN 1 thru SUN 4) may be programmed. A time
period may be anywhere from 1 to 180 minutes in length.
1. Press and hold the
2", followed by, "SP PROG" and "ENTER CODE" show in
the display.
2. Press
button once more and "DO NOT DISTURB" and
"ENTER CODE" flash in the left display.
3. Enter code 1, 2, 3 (first 3 product buttons).
4. "DO NOT DISTURB ENABLED?" flashes in the left display
and YES or NO appears in the right display. Press the ▲ or
▼ buttons to choose YES or NO.
5. Press
button and "M-F 1" shows in the left display and
the time flashes in the right display. Press the ▲ or ▼, or use
product buttons, to change the time.
6. Press
button and "M-F 1" shows in the left display and
"A" or "P" flashes in the right display. Use the ▲ or ▼
buttons to choose AM or PM.
7. Press
button and "M-F 1" shows in left display and far
right character display flashes. Press product buttons to enter
amount of time (up to 180 minutes) during which filtering
will be inhibited, after time entered in step 5.
8. Press
button to move to the next timer period, M-F 2.
9. Repeat steps 5, 6, 7, and 8 for other desired time periods.
37
Model EEG-241, 242, 243, 244
button for 5 seconds until "LEVEL

Hide quick links: