Kyocera TASKalfa 4500i Service Manual page 597

Hide thumbs Also See for TASKalfa 4500i:
Table of Contents

Advertisement

Maintenance
Section
part/location
Scanner
Contact glass
Optical
section
Mirror A
Mirror B
ISU lens
LED mount
RAIL ISU R/F
Original size sensor
ISU
Maintenance
Section
part/location
Transfer
Transfer belt unit
section
User
600K/1200K
call
-
Clean
Clean
-
Clean
-
Clean
-
Check
-
Replace
Lubricat
-
ion
Check
-
Clean
Check
-
Replace
User
600K/1200K
call
-
Replace
2-4-5
Points and cautions
DP slit glass: CL dry cloth or alco-
hol wet cloth is strictly prohibited.
When installing DP, CL with dry
cloth.Contact glass for original:
CL alcohol or dry cloth.(Face
side)
Only when unusual image (line or
stain) appear,wipe the back side
with dry cloth after cleaning with
alcohol only. (Back side)
Clean:airblow after dry cloth only
when unusual image(line) arises.
Clean:airblow after dry cloth only
when unusual image(line) arises.
2pcs
Clean:airblow after dry cloth only
when unusual image(line) arises.
Replace if there are image prob-
lems.
Apply grease if abnormal sound
and jitter image appears
Optical rail grease PG-671(P/
N:60170000)
Alcohol or dry cloth if there is
problem.(lighting part and light
reception part.)
Replace if there are image prob-
lems.
Points and cautions
Every 600k Replace. (MK KIT)
2LL/2LJ/2LH-2
Page
P.1-5-22
Page
P.1-5-35

Hide quick links: