12. Remove two wire holders.
13. Remove the connector (YC27) from
feed PWB 1.
14. Remove three screws.
15. Unhook two hooks and then remove
heater box assembly.
Connector
(YC27)
Wire holder
Wire holder
Figure 1-5-100
Heater box
assembly
Figure 1-5-101
1-5-60
2LL/2LJ/2LH
Feed PWB 1
Screw
Hook
Hook
Heater box
assembly
Screws