Kyocera TASKalfa 4500i Service Manual page 571

Hide thumbs Also See for TASKalfa 4500i:
Table of Contents

Advertisement

Connector
Pin
30
DRM_MOT_CLR_
YC2
REM
Connected to
31
DLP_MOT_BK_DI
engine PWB
R
32
DLP_MOT_BK_RD
Y
33
DLP_MOT_BK_CL
K
34
DLP_MOT_BK_RE
M
35
DRM_MOT_BK_B
RK
36
DRM_MOT_BK_DI
R
37
DRM_MOT_BK_R
DY
38
DRM_MOT_BK_CL
K
39
DRM_MOT_BK_R
EM
40
GND
41
TRANS_MOT_BRK
42
TRANS_MOT_DIR
43
TRANS_MOT_RDY
44
TRANS_MOT_CLK
45
TRANS_MOT_RE
M
46
TCON_SET
47
DU_ENTER_SENS
48
EXIT_FAN
49
DU_MOT_REM
50
GND
1
+24V1
YC3
Connected to
2
+24V1
engine PWB
3
GND
4
GND
5
+12V
6
GND
7
+5V
8
GND
Signal
I/O
-
-
I
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC (pulse) DEVM clock signal
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC (pulse) DRM clock signal
I
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC (pulse) TCM clock signal
I
0/3.3 V DC
-
-
O
0/3.3 V DC
I
0/24 V DC
I
0/3.3 V DC
-
-
O
24 V DC
O
24 V DC
-
-
-
-
O
12 V DC
-
-
O
5 V DC
-
-
Voltage
Not used
DEVM drive switch signal
DEVM ready signal
DEVM: On/Off
DRM break signal
DRM drive switch signal
DRM ready signal
DRM: On/Off
Ground
TCM break signal
TCM drive switch signal
TCM ready signal
TCM: On/Off
Not used
DUS1: On/Off
EFM: On/Off
DUM1/DUCL1: On/Off
Ground
24 V DC power to EPWB
24 V DC power to EPWB
Ground
Ground
12 V DC power to EPWB
Ground
5 V DC power to EPWB
Ground