Code
Contents
1040
PF lift motor 2 error
(paper feeder)
After cassette 4 is inserted,
PF lift sensor 2 does not turn
on within 12 s. This error is
detected 5 times successively.
During driving the motor, the
lift overcurrent protective
monitor signal is detected for
1 s or more 5 times succes-
sively. However, the first 1 s
after motor is turned on is
excluded from detection.
1100
PF lift motor 1 error
(large capacity feeder)
After cassette 3 is inserted,
PF lift sensor 1 does not turn
on within 23 s. This error is
detected 5 times successively.
During driving the motor, the
lift overcurrent protective
monitor signal is detected for
200 ms or more 5 times suc-
cessively. However, the first 1
s after PF lift motor 1 is turned
on is excluded from detection.
1110
PF lift motor 2 error
(large capacity feeder)
After cassette 4 is inserted,
PF lift sensor 2 does not turn
on within 23 s. This error is
detected 5 times successively.
During driving the motor, the
lift overcurrent protective
monitor signal is detected for
200 ms or more 5 times suc-
cessively. However, the first 1
s after PF lift motor 2 is turned
on is excluded from detection.
Causes
Defective bottom
Check to see if the bottom plate can move
plate elevation
smoothly and repair it if any problem is
mechanism in the
found.
cassette.
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
PF lift motor 2 and PF main PWB (YC7)
Defective drive
Check if the gears rotate smoothly. If not,
transmission sys-
grease the bushes and gears. Check for
tem of motor.
broken gears and replace if any.
Defective PF lift
Replace the PF lift motor 2.
motor 2.
Defective PF main
Replace the PF main PWB (Refer to the ser-
PWB.
vice manual for the paper feeder).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
PF lift motor 1 and PF main PWB (YC7)
Defective drive
Check if the gears rotate smoothly. If not,
transmission sys-
grease the bushes and gears. Check for
tem of motor.
broken gears and replace if any.
Defective PF lift
Replace the PF lift motor 1.
motor 1.
Defective PF main
Replace the PF main PWB (Refer to the ser-
PWB.
vice manual for the paper feeder).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
PF lift motor 2 and PF main PWB (YC7)
Defective drive
Check if the gears rotate smoothly. If not,
transmission sys-
grease the bushes and gears. Check for
tem of motor.
broken gears and replace if any.
Defective PF lift
Replace the PF lift motor 2.
motor 2.
Defective PF main
Replace the PF main PWB (Refer to the ser-
PWB.
vice manual for the paper feeder).