Checking/Clearing The Transfer Count; Setting Transfer High-Voltage Timing - Kyocera TASKalfa 4500i Service Manual

Hide thumbs Also See for TASKalfa 4500i:
Table of Contents

Advertisement

Item No.
U127

Checking/clearing the transfer count

Description
Displays and clears the counts of the transfer counter.
Purpose
To check the count or drive time after replacement of the transfer belt unit. Also to clear the
counts after replacing transfer belt unit.
Method
1. Press the start key. The current counts of the transfer counter is displayed.
Belt(Cnt)
Belt(Time)
Clearing
1. Select [Clear].
2. Press the start key. The counter value is cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U128

Setting transfer high-voltage timing

Description
Adjusts the ON/OFF timing of transfer high-voltage output.
Purpose
Basically, the setting need not be changed. If any problem such as faulty images or dirt on the
back surface occurs, change the setting.
Method
1. Press the start key.
2. Select the item to set.
3. Change the value using the +/- keys or numeric keys.
Display
On Timing
1st
Off Timing
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Display
Transfer belt unit count value
Transfer belt unit drive time
Description
Transfer ON timing adjustment
value (first side)
Transfer OFF timing adjust-
ment value
Description
Description
Setting
range
-200 to 200
-200 to 200
1-3-74
2LL/2LJ/2LH-1
Initial setting
35ppm 45ppm 55ppm
-20
-18
-15
-13
-15
-18