(9) Direction of installing the principal fan motors

When detaching or refitting the fan motors, be careful of the airflow direction (intake or exhaust).
Eject front fan motor
(Rating label:inside)
Developer fan motor 2
(Rating label:outside)
Developer fan motor 1
(Rating label:outside)
Eject rear fan motor
(Rating label:outside)
Toner fan motor
(Rating label:outside)
Power source fan motor
(Rating label:inside)
Fuser front fan motor 1
(Rating label:inside)
Fuser rear fan motor
(Rating label:outside)
Controller fan motor
(Rating label:inside)
Exhaust fan motor
(Rating label:inside)
Heater fan motor
(Rating label:inside)
LSU fan motor
(Rating label:inside)
Figure 1-5-129
1-5-80
Eject fan motor 2
(Rating label:inside)
Eject fan motor 1
(Rating label:inside)