Connector
Pin
31
MPF_JAM
YC1
Connected to
32
MPF_LIFT_DOWN
engine PWB
33
MPF_LIFT_UP
34
MPF_PPR_SET
35
3.3V3
36
MPF_LNG
37
MPF_WID3
38
MPF_WID2
39
MPF_WID1
40
MPF_TABLE
41
FSR_MOT_BRK
42
FSR_MOT_DIR
43
GND
44
FSR_MOT_RDY
45
FSR_MOT_CLK
46
FSR_MOT_REM
47
FSR_CL
48
MAIN_HEAT
49
SUB_HEAT
50
ZEROC
51
EXIT_REAR_FAN_
H
52
EXIT_REAR_FAN_
L
53
GND
54
JOB_SOL_REM
55
JOB_OPEN_SENS
56
JOB_MOT_DIR
57
JOB_MOT_CLK
58
JOB_MOT_REM
59
JOB_SET
60
GND
Signal
I/O
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
I
3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC (pulse) FUM clock signal
I
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC (pulse) Zero-cross signal
I
0/24 V DC
I
0/24 V DC
-
-
I
0/24 V DC
O
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC (pulse) JSEM clock signal
I
0/3.3 V DC
O
0/3.3 V DC
-
-
Voltage
MPFS: On/Off
MPLS2: On/Off
MPLS1: On/Off
MPPS: On/Off
3.3 V DC power from EPWB
MPPLSW: On/Off
MPPWSW: On/Off
MPPWSW: On/Off
MPPWSW: On/Off
MPTSW: On/Off
FUM break signal
FUM drive switch signal
Ground
FUM ready signal
FUM: On/Off
Not used
FH1: On/Off
FH2: On/Off
ERFM: On/Off
ERFM: On/Off
Ground
JSFSSOL: On/Off
JSOCS: On/Off
JSEM drive switch signal
JSEM: On/Off
Job separator set signal
Ground
2-3-51
2LL/2LJ/2LH
Description