Item No.
U127
Checking/clearing the transfer count
Description
Displays and clears the counts of the transfer counter.
Purpose
To check the count after replacement of the transfer roller. Also to clear the counts after replacing
transfer roller.
Method
1. Press the start key. The current counts of the transfer counter is displayed.
Cnt
Clearing
1. Select [Clear].
2. Press the start key. The counter value is cleared.
Setting
1. Change the counter value using the cursor left/right keys or numeric keys.
2. Press the start key. The counter value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Displaying the temperature and humidity outside the machine
U139
Description
Displays the detected temperature and humidity outside the machine.
Purpose
To check the temperature and humidity outside the machine.
Method
1. Press the start key. The detected temperature and humidity are displayed.
External Temp
External Humidity
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Display
Transfer counter value
Display
External temperature (C)
External humidity (g/m
Description
Description
Description
)
3
1-3-44