6.5

Changing the assignment of the control terminals X5 and X6

6.5.1

Free configuration of digital input signals

Description
Codes for parameter setting
Code
Possible settings
No.
Name
Lenze Selection
C0114
1 DIGIN1 pol
0
2 DIGIN2 pol
0
3 DIGIN3 pol
0
4 DIGIN4 pol
1
5 DIGIN5 pol
0
5 DIGIN6 (ST) pol
0
EDSVF9383V EN 7.1−04/2012
Changing the assignment of the control terminals X5 and X6
Free configuration of digital input signals
}
Danger!
If you select a configuration in C0005, the signal assignment of
the inputs and outputs will be overwritten with the
corresponding basic assignment!
Adapt the signal assignment to your wiring!
ƒ
ƒ Internal digital signals can be freely linked with external digital signal
sources. This serves to establish a freely configurable control of the
drive controller.
– Digital inputs X5/E1 ... X5/E5
ƒ A signal source can be linked with several targets. Ensure reasonable
linkages for not activating functions that are mutually exclusive (e. g.
linking a digital input with quick stop and DC injection braking at the
same time).
0
High active
HIGH level is
active
1
LOW active
LOW level is active
l
IMPORTANT
Inversion of digital input signals at
X5, function block DIGIN
Terminal X5/E1
Terminal X5/E2
Terminal X5/E3
Terminal X5/E4
Terminal X5/E5
Terminal X5/ST
6.5
6.5.1
^
6.5−1
See System
Manual
(extension)
6.5−1