Download Print this page

Fault And Warning Messages; Fault & Warning Indicators At The Device; Fault & Warning Details With A Connected Device - Kollmorgen AKD Fault Card

Hide thumbs Also See for AKD:

Advertisement

2 Fault and Warning Messages

When a fault occurs a specific fault reaction is executed by the drive. Depending on the fault, the reaction can
be to:
Controlled stop, which slows down any motion to zero velocity (see also CS.VTHRESH and CS.TO )
l
and disables the power stage.
Disable power stage, which immediately disables the power stage (also known as coast to stop).
l
Dynamic brake, which slows down the motor load by shorten the motor phases.
l
If the drive has a fault relay, it is immediately open when a fault occurs.
2.1 Fault & Warning Indicators at the Device
For devices with two 7-segments display
The display on the front panel shows the number of the fault that occurred. If a warning is issued prior to the
fault, the warning is shown on the segment and has the same number as the associated fault.
The left 7 segment display shows "F" for a fault or "n" for a warning. The right one shows the fault or warning
number as follows: "x" [break] "y" [break] "z" [break], where xyz describes the number. The highest priority
fault is displayed. Multiple faults may be present when a fault condition is occurring.
For devices with one 7-segment display
The display on the front panel shows the number of the fault that occurred. If a warning is issued prior to the
fault, the warning is shown on the segment and has the same number as the associated fault.
The 7 segment shows the fault or warning and the number through the following sequence: "F" or "n" [break]
"x" [break] "y" [break] "z" [break], The highest priority fault is displayed. Multiple faults may be present when a
fault condition is occurring.
For devices without any display, but with a LED
A multicolor LED on the device shows if a fault or warning is occurring. Faults are indicated with a red blink-
ing. Warnings with a yellow blinking. When connected to workbench, the main screen shows the "virtual" two
segment display from the device.
2.2 Fault & Warning Details with a Connected Device
With the device connected to workbench, the main screen shows a "virtual" 7-segment display, with appro-
priate sequence for a fault / warning code. The status bar at the button of workbench shows if a warning or
fault is active. The faults and warnings screen shows the details of the actual faults as well as the fault his-
tory. In the terminal, the entire list of faults can be read by DRV.FAULTS. This command can also be used by
any external controller or HMI that is connected to the device. A similar command for warnings is
DRV.WARNINGS.