G94: Feed per minute (non-synchronized feed)
The commands from the block are commanded at a feed speed of one minute [mm/min].
Code
Program
G94
G94
Processing details
• By commanding G94, the values that follow F can be commanded at a feed speed of one minute [mm/min].
• The G94 command is modal. G94 mode is valid when transitioning to G-code control or after reset.
5 G-CODE CONTROL PROGRAMS
5.6 G-Code
5
161