G-Code Control Axis Parameter - Mitsubishi Electric MELSEC iQ-R16MTCPU Programming Manual

Motion controller, g-code control, melsec iq-r series
Hide thumbs Also See for MELSEC iQ-R16MTCPU:
Table of Contents

Advertisement

4.2

G-Code Control Axis Parameter

Set the parameters for the axis information of each axis on each line for G-code control.
[Motion Control Parameter][G-code Control Parameter][G-code Control Axis Parameter]
No.
Item
1
Line axis
Axis No.
information
2
Axis name
3
Rotation axis
4
Stored
Software limit -
stroke limit
5
Software limit +
6
Speed/
Fast forward
time
speed
constant
7
Cutting feed
clamp speed
8
G0 time
constant (linear)
9
G1 time
constant (linear)
10
Rotation
Rotation axis
*2
axis
type
information
11
Tandem
Master control
function
axis name
4 G-CODE CONTROL PARAMETERS
82
4.2 G-Code Control Axis Parameter
Default value
1
0
*2
0
-4
-99999999(10
[mm])
-4
99999999(10
[mm])
2000[mm/min]
2000[mm/min]
1000[ms]
1000[ms]
0
0
*2
Setting range
0:
No setting
1 to 64: Axis No.
0: No setting
1: X
2: Y
3: Z
4: A
5: B
6: C
7: U
8: V
9: W
0: Linear axis
1: Rotation axis
■When linear axis is set
-4
-99999999 to 99999999(10
[mm])
■When rotation axis is set
-4
-99999999 to 99999999(10
[degree])
■When linear axis is set
1 to 1000000[mm/min]
■When rotation axis is set
1 to 1000000[degree/min]
■When linear axis is set
1 to 1000000[mm/min]
■When rotation axis is set
1 to 1000000[degree/min]
1 to 4000[ms]
1 to 4000[ms]
0: Shortcut invalid
1: Shortcut valid
3: All linear coordinates
0: No setting
1: X
2: Y
3: Z
4: A
5: B
6: C
7: U
8: V
9: W
Direct
Indirect setting
*1
setting
Valid/
Valid/
Fetch
invalid
invalid
cycle
(Required
size)
Reference
section
Page
83
Page
83
Page
83
Page
84
Page
85
Page
85
Page
85
Page
85
Page
86
Page
87

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r64mtcpuMelsec iq-r32mtcpu

Table of Contents