Mitsubishi Electric MELSEC iQ-R16MTCPU Programming Manual page 70

Motion controller, g-code control, melsec iq-r series
Hide thumbs Also See for MELSEC iQ-R16MTCPU:
Table of Contents

Advertisement

Axis status
: Available : Not available
Device No.
MELSEC iQ-R
Q series Motion
Motion device
compatible
assignment
device
assignment
M32400+32n
M2400+20n
M32401+32n
M2401+20n
M32402+32n
M2402+20n
M32403+32n
M2403+20n
M32404+32n
M2404+20n
M32405+32n
M2405+20n
M32406+32n
M2406+20n
M32407+32n
M2407+20n
M32408+32n
M2408+20n
M32409+32n
M2409+20n
M32410+32n
M2410+20n
M32411+32n
M2411+20n
M32412+32n
M2412+20n
M32413+32n
M2413+20n
M32414+32n
M2414+20n
M32415+32n
M2415+20n
M32416+32n
M2416+20n
M32417+32n
M2417+20n
M32418+32n
M2418+20n
M32419+32n
M2419+20n
M32420+32n
to
M32431+32n
3 G-CODE CONTROL DEDICATED SIGNALS
68
3.12 Internal Relay (M)/Data Register (D) Availability
Symbol
Signal name
St.1060
Positioning start complete
St.1061
Positioning complete
St.1062
In-position
St.1063
Command in-position
St.1064
Speed controlling
St.1065
Speed/position switching latch
St.1066
Zero pass
St.1067
Error detection
St.1068
Servo error detection
St.1069
Home position return request
St.1070
Home position return complete
St.1071
External
FLS
signals
St.1072
RLS
St.1073
STOP
St.1074
DOG/CHANGE
St.1075
Servo ready
St.1076
Torque limiting
Unusable
St.1079
M-code outputting
Unusable
During
Remarks
G-code
control
Turns OFF at G-code control start.
Updated every operation cycle.
Turns OFF at G-code control start.
Errors detected by G-code control are not
updated. Errors detected by other than
G-code control are updated.
When turned ON, a minor error (error
code: 19A6H) occurs at G-code control
request.
When turned ON, it turns OFF at G-code
control start.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r64mtcpuMelsec iq-r32mtcpu

Table of Contents