3.2

G-Code Control Common Control Device

Device No.
MELSEC iQ-R
Q series Motion
Motion device
compatible
assignment
device
assignment
D54262
D54263
D54264
D54265
D54266
D54267
D54268
D54269
D54270
D54271
D54272
D54273
D54274
D54275
D54276
D54277
[Cd.3305] Program No. for loading while running (D54264)
This register is for loading the G-code program of the program No. specified in "[Rq.3344] Program load request while running
(D54225.0)".
Item
Program No.
3 G-CODE CONTROL DEDICATED SIGNALS
30
3.2 G-Code Control Common Control Device
Symbol
Signal name
Unusable
Cd.3305
Program No. for loading while running
Unusable
Setting range
1 to 256
Refresh cycle
Fetch cycle
At running
program load
request ON
Signal type
Command
device