Permissible compensation value of arc center deviation
Set the permissible compensation value for deviation of the center coordinate value of R-specified circular interpolation. When
the deviation between "line connecting the start point and end point" and "command radius 2" is less than or equal to the
permissible value, a correction is made so that the mid point of the line connecting the start point and end point becomes the
arc center.
• When setting value<0: 0 (No compensation of center deviation)
• When setting value=0: 2minimum setting unit (0.0001)
• When setting value>0: Set value

Override setting

Automatic corner override
Set the override value of automatic corner override.
Setting "0[%]", or "100[%]" disables automatic corner override.
Automatic corner override maximum angle
Set the maximum angle of the corner for automatic deceleration by automatic corner override.
Setting "0[degree]" or "180[degree]" disables automatic corner override.
Length before automatic corner override corner
Set the position for starting deceleration for the corner of automatic corner override.
Set the distance from the corner to the point where deceleration starts.
Fast forward rate override
Set the device for setting the ratio of fast forward rate override. Override can be applied in 1[%] increments against the fast
forward speed.
Set the following value to the specified device.
Setting range
0 to 100[%]
Cutting feed rate override
Set the device for setting the ratio of cutting feed rate override. Override can be applied in 1[%] increments against the feed
speed command set in the G-code program.
Set the following value to the specified device.
Setting range
0 to 327[%]
Override cancel
Set the device for cancelling override.
By turning ON the set device, the override applied to the cutting feed rate override in automatic operation becomes "100[%]".
This device is "disabled" for automatic corner override, and fast forward rate override.