3.6
G-Code Control Line Control Device
Device No.
MELSEC iQ-R Motion
device assignment
D54278 to D54293
D54294 to D54309
• Details for each line
Device No.
MELSEC iQ-R
Q series Motion
Motion device
compatible
assignment
device
assignment
D54278+16s
D54279+16s
D54280+16s
D54281+16s
D54282+16s
D54283+16s
D54284+16s
D54285+16s
D54286+16s
D54287+16s
D54288+16s
D54289+16s
D54290+16s
D54291+16s
D54292+16s
D54293+16s
[Cd.3320] Program No. setting register (D54278+16s)
This setting register is for starting the G-code program of the specified program No.
Refer to automatic operation start (cycle start) for details. (Page 207 Automatic operation start (cycle start))
Item
Program No.
[Cd.3321] Sequence No. setting register (D54280+16s, D54281+16s)
This setting register is for starting a G-code program from the block of the specified sequence No.
Refer to automatic operation start (cycle start) for details. (Page 207 Automatic operation start (cycle start))
Item
Sequence No.
[Cd.3322] Block No. setting register (D54282+16s, D54283+16s)
This setting register is for starting a G-code program from the block of the specified block No.
Refer to automatic operation start (cycle start) for details. (Page 207 Automatic operation start (cycle start))
Item
Block No.
Signal name
Q series Motion compatible
device assignment
Line 1 G-code control line control device
Line 2 G-code control line control device
Symbol
Signal name
Cd.3320
Program No. setting register
Unusable
Cd.3321
Sequence No. setting register
Cd.3322
Block No. setting register
Unusable
Setting range
1 to 256
Program No.
0 to 99999
Setting range
0 to 99999
Refresh cycle
Fetch cycle
G-code control
operation cycle
G-code control
operation cycle
3 G-CODE CONTROL DEDICATED SIGNALS
3.6 G-Code Control Line Control Device
3
Signal type
Command signal
Command signal