Optimum Optiturn TU 2506 Operating Manual page 147

Table of Contents

Advertisement

Available languages

Available languages

Interval
Where?
First after 200
operating
hours,
then
every year
every month
Maintenance
Version 1.0.1
2014-05-16
What?
How?
For oil change use an appropriate collecting tray of suffi-
cient capacity.
Unscrew the screw from the drain hole.
Unscrew the screw from the filler hole.
Close the drain hole if no more oil drains.
Refill with Mobilgear 627 or an equivalent oil up to the ref-
erence mark in the centre of the sight glass using a suita-
ble funnel in the filling hole.
Oil change
Lubricate all oilers with machine oil , do not use a grease
gun or similar greasing equipment. Use the oil bottle in
the delivery volume.

"Operating material" on page 95
Lubricating
Original operating instructions
OPTIMUM
M A S C H I N E N - G E R M A N Y
Outlet
filler hole
Img.4-2: gear openings
Oiler cup
Img.4-3: example, oiler on TU2807
TU2506 | TU2506V | TU2807 | TU2807V