3.2.1
Setting and activating/deactivating limit stops
Functionality
In the main screen of MM+, limit stops can be entered into the input fields "-X/-Z/+X/+Z".
In the following screen, the cursor is located in the desired input field (with an orange background).
Parameter
Parameter
Description
ON
The limit stop is activated.
OFF
The limit stop is deactivated.
- X
Negative absolute position of the limit stop of the X axis.
The axis stops automatically when both of the following are met:
The limit stop is active.
•
The specified axis traverses in the negative direction and reaches the absolute limit stop position.
•
+X
Positive absolute position of the limit stop of the X axis.
The axis stops automatically when both of the following are met:
The limit stop is active.
•
The specified axis traverses in the positive direction and reaches the absolute limit stop position.
•
-Z
Negative absolute position of the limit stop of the Z axis.
The axis stops automatically when both of the following are met:
The limit stop is active.
•
The specified axis traverses in the negative direction and reaches the absolute limit stop position.
•
+Z
Positive absolute position of the limit stop of the Z axis.
The axis stops automatically when both of the following are met:
The limit stop is active.
•
The specified axis traverses in the positive direction and reaches the absolute limit stop position.
•
Programming and Operating Manual (Manual Machine Plus (MM+), Turning)
01/2017
9