Chapter 6 – Meter Commands
per component(8):
ddddddddd = delivered gross quantity in whole units
ddddddddd = delivered net quantity in whole units
Note: if the Use Hundredths W&M RCU parameter is enabled, the gross and net quantity value will have an implied two decimal places.
Sddddd = signed component batch average temp in tenths or hundredths
sddddd = component batch average pressure in tenths or hundredths
dddddd = depending on API table selected,
sddddd = signed component current temp in hundredths
sddddd = signed component current pressure in hundredths
sddddd = signed component current density in tenths
sddddd = signed component current relative density in ten thousands
sddddd = signed component current bsw hund
sdddd = signed component current api gravity tenths
sddddd = signed batch average bsw hund
sdddd = signed batch average api gravity tenths
ddddddddd = component meter delivered gross quantity in whole units
ddddddddd = component meter delivered net quantity in whole units
sddddd = signed component meter batch average temp in tenths or hundredths
sddddd = component meter batch average pressure in tenths or hundredths
dddddd = depending on API table selected,
sddddd = signed component meter current temp in hundredths
sddddd = signed component meter current pressure in hundredths
sddddd = signed component meter current density in tenths
sddddd = signed component meter current relative density in ten thousands
sddddd = signed component meter current bsw hund
sdddd = signed component meter current api gravity tenths
sddddd = signed meter batch average bsw hund
sdddd = signed meter batch average api gravity tenths
ddddddddd = delivered mass quantity in whole units
Modbus :
Where: p = preset (0-11), c = component (0-7)
Read Only Register=4372+p*8+c, Len=2, 32-Bit Integer (ddddddddd (gross))
Read Only Register=4564+p*8+c, Len=2, 32-Bit Integer (ddddddddd (net))
Read Only Register=4756+p*8+c, Len=2, 32-Bit Integer (sddddd (component average temp))
Read Only Register=4948+p*8+c, Len=2, 32-Bit Integer (sddddd (component average pressure))
Read Only Register=5140+p*8+c, Len=2, 32-Bit Integer (dddddd (component average density/rel.
dens./gravity))
Read Only Register=5332+p*8+c, Len=2, 32-Bit Integer (sddddd (component current temp))
Read Only Register=5524+p*8+c, Len=2, 32-Bit Integer (sddddd (component current pressure))
component batch average density in tenths OR
component batch average relative density in ten thousands OR
component batch average gravity in tenths
component meter batch average density in tenths OR
component meter batch average relative density in ten thousands OR
component meter batch average gravity in tenths