Chapter 6 – Meter Commands
qqqqqqqqq= preset quantity in whole units
ddddddddd = delivered gross quantity in whole units
ddddddddd = delivered net quantity in whole units
Note: if the Use Hundredths W&M RCU parameter is enabled, the gross and net quantity value will have an implied two decimal places.
Sddddd = signed batch average temp in tenths or hundredths
sddddd = signed batch average pressure in tenths or hundredths
dddddd = depending on API table selected,
batch average density in tenths OR
batch average relative density in ten thousands OR
batch average gravity in tenths
ddddd = preset gross flow rate in whole units
Modbus :
Where: p = preset (0-11)
Read Only Register=4000+p, Len=1, 16-Bit Integer (wwww)
Read Only Register=4012+p, Len=1, 16-Bit Integer (xxxx)
Read Only Register=4024+p, Len=1, 16-Bit Integer (yyyy)
Read Only Register=4036+p, Len=2, 32-Bit Integer (qqqqqqqqq)
Read Only Register=4060+p, Len=2, 32-Bit Integer (ddddddddd (gross))
Read Only Register=4084+p, Len=2, 32-Bit Integer (ddddddddd (net))
Read Only Register=4108+p, Len=2, 32-Bit Integer (sddddd (temp))
Read Only Register=4132+p, Len=2, 32-Bit Integer (sddddd (pressure))
Read Only Register=4156+p, Len=2, 32-Bit Integer (dddddd)
Read Only Register=4180+p, Len=1, 16-Bit Integer (ddddd (rate))
36
Need help?
Do you have a question about the MultiLoad II and is the answer not in the manual?
Questions and answers