Chapter 7 – Register Operations
U200aabbccddeeff => 0?0200
Where:
aabb = BOL Line and Position Number for the BOL Number
ccdd = BOL Line and Position Number for the Card Number
eeff = BOL Line and Position Number for the Company
Modbus:
Read/Write Register=350, Len=1, 16-Bit Integer (aa)
Read/Write Register=351, Len=1, 16-Bit Integer (bb)
Read/Write Register=352, Len=1, 16-Bit Integer (cc)
Read/Write Register=353, Len=1, 16-Bit Integer (dd)
Read/Write Register=354, Len=1, 16-Bit Integer (ee)
Read/Write Register=355, Len=1, 16-Bit Integer (ff)
R201 => 0?0201aabbccddeeffgghh
U201aabbccddeeffgghh => 0?0201
Where:
aabb = BOL Line and Position Number for the Load Date
ccdd = BOL Line and Position Number for the Load Start Time
eeff = BOL Line and Position Number for the Load End Time
gghh = BOL Line and Position Number for the Corrected To
Modbus:
Read/Write Register=356, Len=1, 16-Bit Integer (aa)
Read/Write Register=357, Len=1, 16-Bit Integer (bb)
Read/Write Register=358, Len=1, 16-Bit Integer (cc)
Read/Write Register=359, Len=1, 16-Bit Integer (dd)
Read/Write Register=360, Len=1, 16-Bit Integer (ee)
Read/Write Register=361, Len=1, 16-Bit Integer (ff)
Read/Write Register=362, Len=1, 16-Bit Integer (gg)
Read/Write Register=363, Len=1, 16-Bit Integer (hh)
R202 => 0?0202aabbccddeeff
U202aabbccddeeff => 0?0202
Where:
aabb = BOL Line and Position Number for the Hazard Message
Modbus:
Read/Write Register=364, Len=1, 16-Bit Integer (aa)
Read/Write Register=365, Len=1, 16-Bit Integer (bb)
R203 => 0?0203aabbccddeeffgghhiijjkk
U203aabbccddeeffgghhiijjkk => 0?0203
Where:
aa = BOL Line Number to Start Product Totals
bb = BOL Position Number for the Product Code
cc = BOL Position Number for the Product Description
dd = BOL Position Number for the Product Gross Volume