Real-Time Preset Total Net Totalizers; Real-Time Preset Total Mass Totalizers; Real-Time Sampler Total Gross Totalizers - Toptech MultiLoad II Manual

Hide thumbs Also See for MultiLoad II:
Table of Contents

Advertisement

Chapter 7 – Register Operations
Note: if the Use Hundredths W&M RCU parameter is enabled, the preset, meter and component gross quantity values will have an implied
two decimal places.
AAAAAAAAA... = Additive Total Gross Totalizers in Thousands, (16 additives, 9 digits per
totalizer.)
Modbus:
Where: p = preset (0-11), m = meter (0-4), c = component (0-7), a=additive (0-15)
Read Only Registers=3000+2*p, Len=2, 32-Bit Integer (PPPPPPPPP)
Read Only Registers=3024+2*(5*p+m), Len=2, 32-Bit Integer (MMMMMMMMM)
Read Only Registers=3144+2*(8*p+c), Len=2, 32-Bit Integer (CCCCCCCCC)
Read Only Registers=3336+2*(16*p+a), Len=2, 32-Bit Integer (AAAAAAAAA)
Note: Last Gross Totalizer register used=3719
7.2.16 113 - R
-T
EAL
IME
R113ppp
Where:
ppp = The specified zero-based preset or load arm number (000-011).
PPPPPPPPP = Preset Total Net Totalizer
CCCCCCCCC... = Component Total Net Totalizers (8 components, 9 digits per totalizer.)
Note: if the Use Hundredths W&M RCU parameter is enabled, the preset and component net quantity values will have an implied two
decimal places.
Modbus:
Where: p = preset (0-11), c = component (0-7)
Read Only Registers=3720+2*p, Len=2, 32-Bit Integer (PPPPPPPPP)
Read Only Registers=3744+2*(8*p+c), Len=2, 32-Bit Integer (CCCCCCCCC)
Note: Last Net Totalizer register used=3935
7.2.17 114 - R
-T
EAL
IME
R114ppp
Where:
ppp = The specified zero-based preset or load arm number (000-011).
PPPPPPPPP = Preset Total Mass Totalizer
CCCCCCCCC... = Component Total Mass Totalizers (8 components, 9 digits per totalizer.)
Note: if the Use Hundredths W&M RCU parameter is enabled, the preset and component mass quantity values will have an implied two
decimal places.
Modbus:
Where: p = preset (0-11), c = component (0-7)
Read Only Registers=11720+2*p, Len=2, 32-Bit Integer (PPPPPPPPP)
Read Only Registers=11744+2*(8*p+c), Len=2, 32-Bit Integer (CCCCCCCCC)
Note: Last Mass Totalizer register used=11935
7.2.18 120 - R
-T
EAL
IME
R120ppp
Where:
ppp = The specified zero-based preset or load arm number (000-011).
SSSSSSSSS = Sampler Total Gross Totalizer
Note: if the Use Hundredths W&M RCU parameter is enabled, the preset and component mass quantity values will have an implied two
decimal places.
P
T
N
T
RESET
OTAL
ET
OTALIZERS
=>
0?0113pppPPPPPPPPPCCCCCCCCC...
P
T
M
T
RESET
OTAL
ASS
OTALIZERS
=>
0?0114pppPPPPPPPPPCCCCCCCCC...
S
T
G
T
AMPLER
OTAL
ROSS
=>
0?0112pppSSSSSSSSS
OTALIZERS
13
8

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MultiLoad II and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents

Save PDF