Chapter 7 – Register Operations
ccccc = Promotion Count (00000=no promotion)
ppppp = Promoted Alarm Level as:
rrrrr = Reset Mode as:
ttttt = Alarm_to_host as
Note: only permissive names can be changed, iii=1.
Mmmmmmmmm = Fcm Output Address
Nnnnn = Batch Alarm Mask for Alibilog
Enum{
Modbus:
Read/Write Register=2561, Len=1, 16-Bit Integer (lllll)
Read/Write Register=2562, Len=15, Characters (sssssssssssssss)
Read/Write Register=2577, Len=1, 16-Bit Integer (ccccc)
Read/Write Register=2578, Len=1, 16-Bit Integer (ppppp)
Read/Write Register=2579, Len=1, 16-Bit Integer (rrrrr)
Note: Up to 30 UTF-8 bytes to represent a max of 10 characters.
enum
{
AUTO_CLEAR = 0,
DRIVER_CLEAR = 1,
REMOTE_CLEAR = 2,
PROGRAM_CLEAR = 3,
WM_CLEAR = 4
}promoted_alarm_level;
enum
{
AUTH_TRANS = 0,
CLEAR_PROMOTED = 1,
TIME_2_MIN = 2,
TIME_5_MIN = 3,
TIME_15_MIN = 4,
TIME_30_MIN = 5,
TIME_60_MIN = 6,
TIME_3_HOURS = 7,
TIME_6_HOURS = 8,
TIME_12_HOURS = 9,
TIME_24_HOURS = 10,
}alarm_count_reset_mode;
enum
{
REMOTE = 0,
LOCAL =1,
}alarm_to_host_mode_type
DISABLED
ENABLED
Note: Up to 15 UTF-8 bytes to represent a max of 10 characters.
= 0,
= 1 }
15