Configuration Control; Figure 4-5: Configuration Control Page - Alvarion BreezeMAX PRO 5000 CPE Product Manual

Cpe subscriber units
Table of Contents

Advertisement

Chapter 4 - Operation
3
4
5
Reset and Run from Shadow: select this option to reset the unit and run the
Shadow version after power up. To avoid unintentional actions you will be
prompted to confirm the request.
Set Running Version as Main: when the unit is running the Shadow version
(after selecting Reset and Run from Shadow) without succeeding to complete
network entry, the versions will not be swapped and the unit will boot from the
Main version after the next reset. Select this option if you want to swap
versions so that the running version will become the Main version and will be
the version to be used after reset. To avoid unintentional actions you will be
prompted to confirm the request.
Refresh: select this option to clear the fields.
4.5.5

Configuration Control

BreezeMAX PRO 5000 CPE
If a different IP address is configured in the PC with the TFTP, configure the
TFTP Server IP Address to the same address.
Enter the name of the SW file (as called in the TFTP server) as the SW File
Name.
Select Perform SW Download and confirm the download request. Wait to
receive a success/failure message.
Following a successful download, the loaded SW version becomes the
Shadow version in the unit.

Figure 4-5: Configuration Control Page