Sw Versions Control; Figure 4-4: Sw Versions Control Page - Alvarion BreezeMAX PRO 5000 CPE Product Manual

Cpe subscriber units
Table of Contents

Advertisement

Chapter 4 - Operation
4.5.4

SW Versions Control

The CPE can contain two SW versions:
Main: Normally, each time the CPE resets it will reboot using the version
defined as Main.
Shadow: Normally the Shadow version is the backup version. Each time a new
SW File is downloaded to the CPE, it will be stored as a Shadow version,
replacing the previous Shadow Version.
The typical process of upgrading to a new SW version includes the following steps:
Download the new SW file to the CPE. It will be stored as the Shadow version.
1
Reset and run the unit from its Shadow version. Note that if the new SW file
2
was loaded from StarACS, the Run from Shadow operation will be performed
automatically.
If the unit succeeded to complete network entry, the Shadow and Main
3
versions will be swapped automatically: The currently running version will be
defined as Main and will be used each time the unit reboots. The previous
version is defined now as Shadow.
BreezeMAX PRO 5000 CPE

Figure 4-4: SW Versions Control Page

51
Unit Control Parameters
Product Manual