Chapter 2 - Installation
Insert the cable with the assembled connector through the sealing nut.
2
To expose the groove, lightly squeeze the seal. Carefully insert the cable
3
through the groove.
Insert the cable through the housing and insert the seal at the back end of the
4
housing.
Tighten the sealing nut onto the housing.
5
Stricken the gasket on the front end of the housing.
6
Sealing nut

Figure 2-7: Inserting the IDU COM Cable into the Sealing Cap

Connect the Ethernet cable to the IDU COM RJ-45 connector and tighten the
7
sealing cap.
Route the cable to the location selected for the indoor equipment.
8
Assemble an RJ-45 connector with a protective cover on the indoor end of the
9
IDU-ODU cable. Refer to the pin assignment and color codes in standard
cables described above.
2.1.6.3
Connecting the Antenna Cable (units with external antenna)
To connect the RF cable:
Mount the antenna as close as possible to the ODU.
1
Connect one end of the coaxial RF cable to the RF connector (marked
2
located at the top panel of the unit (see
Connect the other end of the RF cable to the antenna.
3
The RF connectors should be properly sealed to protect against rain and
4
moisture.
BreezeMAX PRO 5000 CPE
Housing
Seal
22
Installing the ODU of the CPE
Gasket
Figure
2-5).
)
Product Manual