Appendix A - Troubleshooting
Problem and Indication
The Ethernet Activity and/or
Integrity LEDs are on, but
no management access
using Telnet or web
browser, and the unit does
not respond to ping.
Scanning failed and/or
Base Station not found:
None of the LINK QUALITY
LEDs illuminate.
Signal is too strong:All LINK
QUALITY LEDs, including
the red LED are on
Authentication Failure: LED
1 (orange) of the LINK
QUALITY bar blinks.
BreezeMAX PRO 5000 CPE
Possible Cause
Wrong IP configuration
Wrong Ethernet port
operation mode
ARP table in the PC
contains a wrong MAC
address for the
192.168.254.251 IP
address (due to a recent
connection to another
CPE).
Bridging table in CPE is full
(expected when Number of
Supported Devices,
configurable from the Base
station's side, is set to a
small number.
Configuration problem
Poor link quality
Signal is too strong-may
cause saturation.
Authentication problem
Corrective Action
Make sure that the PC is on the same subnet as the
unit. The unit's IP address for management
purposes is 192.168.254.251, and the subnet mask
is 255.255.255.0.
Make sure that the speed and duplex settings in the
PC match the configuration in the unit. The default
operation mode is Auto Negotiation, and supported
speeds are 10/100 Mbps, Full or Half Duplex.
Perform arpV-d at the DOS command prompt to
clear the ARP table, and retry the Telnet command
to the unit.
Reset the CPE to clear the table and retry the Telnet
command to the unit.
Verify proper configuration of Frequency Scanning
parameters.
Verify proper configuration of BS ID parameters.
If proper configuration parameters are not known,
press the RESET button for more than 5 seconds to
activate the factory default configuration
Try changing the location of the unit/antenna to
improve link quality using the LINK QUALITY LEDs.
Change the location/direction of the unit/antenna to
reduce signal strength using the LINK QUALITY
LEDs.
Enter User Name and User Password and reset the
unit. If the problem persists, contact the operator.