Introduction To Cpe Management - Alvarion BreezeMAX PRO 5000 CPE Product Manual

Cpe subscriber units
Table of Contents

Advertisement

Chapter 4 - Operation
4.1

Introduction to CPE Management

The units support the TR-069 CPE WAN Management Protocol (CWMP), allowing
efficient management by an Auto Configuration Server (ACS).
In addition, configuration and performance monitoring of a single unit can be
performed either locally (via the Ethernet port) or remotely using any of the
following options:
Using a PC/Notebook with an http browser to access the built-in web
configuration server.
Using TFTP to upload/download a Configuration File.
For local management, the management IP address is 192.168.254.251 with
subnet mask 255.255.255.0.
Remote (over the air) management is done using a WAN management IP address
acquired from a DHCP server as a part of the Network Entry process. The DHCP
server should supply also the IP address of the ACS management station. In the
uplink, the DSCP value of management packets sent by the unit can be
configured only by the remote management system using TR-069 (the default
value is 6).
The Web Configuration Server enables the configuration of all CPE parameters
using a Notebook/PC with a web browser. It also enables downloading of SW files,
control of the running SW version, and downloading/uploading of the
configuration file, enabling simplified and faster configuration process.
The Web Configuration Server also provides a selection of performance monitoring
capabilities, allowing installers and technicians to view information on link quality
and traffic counters. These monitoring capabilities enable performance
verification and problems identification.
To further support local testing, the program also enables temporary control of the
ATPC mechanism.